The machine consists of a load frame and motorized pumping unit. The lower platen has two rollers, the distance between which is adjustable. The upper platen has also roller. Micro-processor based Digital Load Indicator to indicate applied load is fitted in the Pumping unit. The Pumping unit is separate electrically operated, housed in a cabinet. On/Off switch and a slow/fast lever to control rate of loading are fitted on the front panel of the pumping unit. A micro switch and relay fitted inside the Digital Load indicator to protect the unit from over loading.
- Max. Tile size 660 X 660mm
- Direct reading of total applied load in KN
- Direct reading of Flexural strength in N/mm2 - No calculation required
- Peak hold facility
- RS 232 interface (Optional - at extra cost)
- Direct analytical reports on computer (Optional)
- Auto generation of load/time graph. (Optional)
- Overload safety cut out
- Password protected Calibration to prevent Un authorized manipulation
Type of Pumping : | Electrical |
Loading Range : | 100 KN |
Least Count : | 0.1 KN |
Optional Accessories at extra cost : | 1) PC link software 2) Wireless PC link software |